<?xml version="1.0" encoding="UTF-8"?>
<!-- generator="FeedCreator 1.8" -->
<?xml-stylesheet href="https://gloveboxguide.de/lib/exe/css.php?s=feed" type="text/css"?>
<rdf:RDF
    xmlns="http://purl.org/rss/1.0/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
    xmlns:dc="http://purl.org/dc/elements/1.1/">
    <channel rdf:about="https://gloveboxguide.de/feed.php">
        <title>The Glove Box Guide</title>
        <description></description>
        <link>https://gloveboxguide.de/</link>
        <image rdf:resource="https://gloveboxguide.de/lib/exe/fetch.php?media=wiki:logo.png" />
       <dc:date>2026-06-03T09:08:33+00:00</dc:date>
        <items>
            <rdf:Seq>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=analytikgb&amp;rev=1774139765&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=contact&amp;rev=1774371462&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=ea_gb&amp;rev=1774199678&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=gbfunction&amp;rev=1779055049&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=h2osensorgb&amp;rev=1775518991&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=liquidsgb&amp;rev=1779061567&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=manipulationgb&amp;rev=1774133420&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=massegb&amp;rev=1775668783&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=nmrgb&amp;rev=1775574070&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=reactorgb&amp;rev=1774371432&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=sidebar&amp;rev=1779054999&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=solventfiltergb&amp;rev=1775129350&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=start&amp;rev=1774353278&amp;do=diff"/>
                <rdf:li rdf:resource="https://gloveboxguide.de/doku.php?id=tauschgb&amp;rev=1774366970&amp;do=diff"/>
            </rdf:Seq>
        </items>
    </channel>
    <image rdf:about="https://gloveboxguide.de/lib/exe/fetch.php?media=wiki:logo.png">
        <title>The Glove Box Guide</title>
        <link>https://gloveboxguide.de/</link>
        <url>https://gloveboxguide.de/lib/exe/fetch.php?media=wiki:logo.png</url>
    </image>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=analytikgb&amp;rev=1774139765&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-03-22T00:36:05+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>analytikgb</title>
        <link>https://gloveboxguide.de/doku.php?id=analytikgb&amp;rev=1774139765&amp;do=diff</link>
        <description>Preparation of samples in the GB for different analytical methods

	*  NMR
	*  Elemental analysis
	*  Mass spectrometry
	*  XRay diffraction
	*  Powder diffraction</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=contact&amp;rev=1774371462&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-03-24T16:57:42+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>contact</title>
        <link>https://gloveboxguide.de/doku.php?id=contact&amp;rev=1774371462&amp;do=diff</link>
        <description>Contact

Im always looking for tipps, feedback, ideas, contributions, suggestions, etc. If you have anything for me just contact me via mail.

gloveboxguide@gmail.com

My 3D models can be found here (external link).</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=ea_gb&amp;rev=1774199678&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-03-22T17:14:38+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>ea_gb</title>
        <link>https://gloveboxguide.de/doku.php?id=ea_gb&amp;rev=1774199678&amp;do=diff</link>
        <description>Elemental analysis

Small tin capsules proved to be reliable for preparing samples for elemental analysis of sensitive compounds inside a glove box ().
[title]

[ title]

[ title]


To make it easier to take pictures, the process of preparing a sample is shown outside the glove box. The capsules are tiny and relatively soft. Therefore, custom tools are needed to prepare them inside a glove box.</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=gbfunction&amp;rev=1779055049&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-05-17T21:57:29+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>gbfunction</title>
        <link>https://gloveboxguide.de/doku.php?id=gbfunction&amp;rev=1779055049&amp;do=diff</link>
        <description>How a glove box works



	*  Particle filter for inlet/outlet
	*  holes for the gloves in front window
	*  antechamber
	*  pressure regulation
	*  solenoid valve or bubbler
	*  vacuum pump
	*  oxygen sensor
	*  moisture sensor
	*  three way valve on antechamber</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=h2osensorgb&amp;rev=1775518991&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-04-06T23:43:11+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>h2osensorgb</title>
        <link>https://gloveboxguide.de/doku.php?id=h2osensorgb&amp;rev=1775518991&amp;do=diff</link>
        <description>Maintenance of the moisture sensor

The most common type of moisture sensor used in glove boxes has a probe head covered with a layer of phosphoric acid. The phosphoric acid deteriorates over time, which is why it needs to be renewed regularly (approximately every 2,000 hours). One of the manufacturers has created an instructional</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=liquidsgb&amp;rev=1779061567&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-05-17T23:46:07+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>liquidsgb</title>
        <link>https://gloveboxguide.de/doku.php?id=liquidsgb&amp;rev=1779061567&amp;do=diff</link>
        <description>Liquids inside the glove box

Solvent usage is a core requirement in most synthetic chemistry disciplines, so introducing them into a glovebox environment is unavoidable, especially in organometallic chemistry. However, solvent fumes will damage the reactor and other parts of the glovebox over time, so a</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=manipulationgb&amp;rev=1774133420&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-03-21T22:50:20+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>manipulationgb</title>
        <link>https://gloveboxguide.de/doku.php?id=manipulationgb&amp;rev=1774133420&amp;do=diff</link>
        <description>Reaction manipulation

	*  Cooling
	*  Heating
	*  Crystallization
	*  Removal of solvents / Vacuum
	*  Filtration</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=massegb&amp;rev=1775668783&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-04-08T17:19:43+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>massegb</title>
        <link>https://gloveboxguide.de/doku.php?id=massegb&amp;rev=1775668783&amp;do=diff</link>
        <description>Mass spectrometry

There are multiple methods of mass spectrometry and ionization. However, most of these methods are not suitable for organometallic/elementorganic samples, since inert application methods and soft ionization are usually necessary. In these cases, the liquid injection field desorption ionization mass spectrometry (LIFDI-MS) method has proven effective. Samples are introduced through a capillary from a sealed vial with a septum, and the ionization method itself is one of the soft…</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=nmrgb&amp;rev=1775574070&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-04-07T15:01:10+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>nmrgb</title>
        <link>https://gloveboxguide.de/doku.php?id=nmrgb&amp;rev=1775574070&amp;do=diff</link>
        <description>Preparing NMR samples

To prepare NMR samples inside a glovebox, NMR tubes with a Young-type PTFE cap are recommended (). They provide long-lasting leak-tightness and remain tight under vacuum. This is important for bringing samples back into the glovebox through the antechamber.</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=reactorgb&amp;rev=1774371432&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-03-24T16:57:12+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>reactorgb</title>
        <link>https://gloveboxguide.de/doku.php?id=reactorgb&amp;rev=1774371432&amp;do=diff</link>
        <description>Reactor loading

The loading of the reactor will inevitably deteriorate over time when solvents are used inside a glovebox even if a solvent filter is used. The solvent filter just slows this process down significantly and therefore needs regular maintenance itself to protect the reactor loading. The deterioration is due to the reaction of solvent molecules with the surface of the metal based getter material beads. This is especially true for halogenated solvents like dichloromethane. Unlike the…</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=sidebar&amp;rev=1779054999&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-05-17T21:56:39+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>sidebar</title>
        <link>https://gloveboxguide.de/doku.php?id=sidebar&amp;rev=1779054999&amp;do=diff</link>
        <description>Glovebox Guide

	*  How a glovebox works
	*  General maintenance / replacing consumables
	*  Reaction manipulation 
	*  Liquids inside the Glovebox
	*  Tips and tweaks
	*  Analytic
	*  Contact</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=solventfiltergb&amp;rev=1775129350&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-04-02T11:29:10+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>solventfiltergb</title>
        <link>https://gloveboxguide.de/doku.php?id=solventfiltergb&amp;rev=1775129350&amp;do=diff</link>
        <description>Maintenance of the solvent filter

Introduction

 A solvent filter is needed if solvents are handled inside a glove box to protect the reactor and other parts of the system. Some newer systems come with a molecular sieve filter. These filters can be regenerated and do not need to be replaced. However, most glove boxes use a solvent filter filled with activated carbon. This filter must be replaced when it becomes saturated with solvent. It is difficult to determine when this occurs, but when the …</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=start&amp;rev=1774353278&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-03-24T11:54:38+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>start</title>
        <link>https://gloveboxguide.de/doku.php?id=start&amp;rev=1774353278&amp;do=diff</link>
        <description>The Glove Box Guide



Glove boxes are large pieces of laboratory equipment that have become increasingly popular in industry and academia over the years. Nowadays, entire production lines exist inside the inert environments that glove boxes provide. However, in academia, knowledge of how to work with and maintain glove boxes tends to deteriorate over time due to the high personnel turnover (PhD students, postdocs, etc.). Skills and knowledge about glove boxes are not usually taught in lectures …</description>
    </item>
    <item rdf:about="https://gloveboxguide.de/doku.php?id=tauschgb&amp;rev=1774366970&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-03-24T15:42:50+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>tauschgb</title>
        <link>https://gloveboxguide.de/doku.php?id=tauschgb&amp;rev=1774366970&amp;do=diff</link>
        <description>General maintenance / replacing consumables

	*  Gloves
	*  Patching punctures
	*  Solvent filter
	*  Reactor loading
	*  Moisture sensor
	*  Antechamber gasket
	*  Purge / flush the atmosphere
	*  Regeneration of the reactor
	*  Particle filter
	*  Adjusting the three-way-valve</description>
    </item>
</rdf:RDF>
